| NTE Type No. |
Maximum Reverse Stand Off Voltage (Volts) |
Breakdown Voltage @ IT (Volts) |
Maximum Ratings | Temperature Coefficient of BV% / °C | |||||
| Clamping Voltage @ Ipp (1msec) (Volts) |
Reverse Leakage Current @ VR (µA) |
Peak Pulse Current (Amps) | |||||||
| VR | VBR | VC | IR | Ipp | |||||
| Min | Typ | Max | IT mA | ||||||
| 4828 | 15.0 | 16.7 | - | 20.4 | 5.0 | 24.4 | 10.0 | 206.00 | 0.094 |
| 4840 | 24.0 | 26.7 | - | 29.5 | 5.0 | 38.9 | 10.0 | 128.00 | 0.101 |
| 4846 | 30.0 | 33.3 | - | 36.8 | 5.0 | 48.4 | 10.0 | 103.00 | 0.103 |
| 4848 | 33.0 | 36.7 | - | 40.6 | 5.0 | 53.3 | 10.0 | 94.00 | 0.104 |
| 4850 | 36.0 | 40.0 | - | 44.2 | 5.0 | 58.1 | 10.0 | 85.00 | 0.104 |
| 4858 | 48.0 | 53.3 | - | 58.9 | 5.0 | 77.4 | 10.0 | 65.00 | 0.106 |
| 4868 | 64.0 | 71.1 | - | 78.6 | 5.0 | 103.0 | 10.0 | 49.00 | 0.108 |
| Note 1. | A Transient Suppressor is usually selected according to the "Reverse Stand Off Voltage (VR)" which should be equal to or greater than the DC or continuous peak operating voltage level. |
| Note 2. | Steady State Power Dissipation is 8 Watts. Forward Surge Current is 400 Amps. Storage & Operating Temperature Range is -55°C to +175°C. |