| Maximum Peak Repetitive Reverse Voltage, VRRM | 45V |
| Maximum Working Peak Reverse Voltage, VRWM | 45V |
| Maximum DC Blocking Voltage, VR | 45V |
| Maximum RMS Reverse Voltage, VR(RMS) | 31V |
| Maximum Average Rectified Forward Current (VR = 45V, TC = +125°C), IF(AV) Per Leg Total Device |
20A 40A |
| Peak Repetitive Forward Current, IFRM (VR = 45V, Square Wave, 20kHz, TC = +125°C Max) |
40A |
| Non-Repetitive Peak Surge Current, IFSM (Surge applied at rated load conditions halfwave, single phase, 60Hz |
300A |
| Operating Junction Temperature Range, TJ | -65° to +250°C |
| Storage Temperature Range, Tstg | -65° to +250°C |
| Maximum Instantaneous Forward Voltage (IF = 20A), VF | |
| TC = +125°C | 0.50V |
| TC = +25°C | 0.55V |
| Maximum Instantaneous Reverse Current (Rated DC Voltage), IR | |
| TC = +125°C | 10mA |
| TC = +25°C | 100mA |